1*2 Dual Windows FBT Nyawiji Fiber Optic Splitter
Spesifikasi:
| Paramèter | Spesifikasi |
| Nomer Saluran | 1×2 |
| Dawane gelombang operasi (nm) | 1310.1550.1310/1550.1310/1550/1490 |
| Operasi Bandwidth (nm) | ±40 |
| Rasio kopling | Kopling Ratio Insertion Loss (dB) |
| 50/50 | ≤3.6/3.6 |
| 40/60 | ≤4.8/2.8 |
| 30/70 | ≤6.1/2.1 |
| 20/80 | ≤8.0/1.3 |
| 10/90 | ≤11.3/0.9 |
| 15/85 | ≤9.6/1.2 |
| 25/75 | ≤7.2/1.6 |
| 35/65 | ≤5.3/2.3 |
| 45/55 | ≤4.3/3.1 |
| PDL (dB) | ≤0.2 |
| Directivity (dB) | ≥50 |
| Rugi bali (dB) | ≥55 |
Kinerja utama:
| Lebokake mundhut | ≤ 0,2dB |
| mundhut bali | 50dB (UPC) 60dB (APC) |
| Daya tahan | 1000 Kawin |
| Dawane gelombang | 850nm, 1310nm, 1550nm |
Kondisi operasi:
| Suhu operasi | -25°C~+70°C |
| Suhu panyimpenan | -25°C~+75°C |
| Kelembapan relatif | ≤85%(+30°C) |
| Tekanan udara | 70Kpa~106Kpa |
Deskripsi Produk
•Fiber optic coupler, minangka piranti sing dihargai ing sistem serat optik kanthi siji utawa luwih serat input lan siji utawa sawetara serat output.
•Kanggo pamisah optik sing nyawiji, bisa dipérang dadi rasio sing beda-beda.kayata 50/50 yen pamisah malah, utawa 80/20 yen 80% sinyal menyang sisih siji lan mung 20% ing sisih liyane. Minangka asil saka fungsi gedhe.
•Splitter optik minangka bagéyan penting banget ing jaringan optik pasif (PON).
•FTB Fused fiber splitter (coupler) bisa nindakake Single mode (1310/1550nm) lan Multimode (850nm). Jendhela tunggal, jendela dobel lan jendela telu kabeh sing bisa diwenehake.
•Single mode Dual Window Couplers sing Single Mode Splitters karo rasio pamisah ditetepake saka siji utawa loro serat input kanggo 2 serat output.
•Cacah pamisah sing kasedhiya yaiku 1x2 lan 2x2 ing rasio pamisah: 50/50, 40/60, 30/70, 20/80, 10/90, 5/95, 1/99, 60/40, 70/30, 80/20, 90/10, lan 95.
•Dual Window Couplers kasedhiya karo 0.9mm ngeculke tabung single mode serat utawa 250um serat gundhul lan mungkasi utawa unterminated minangka saben kabutuhan.
•DWC sing ora disambungake ora ana konektor supaya gampang disambungake utawa disambungake.
•Diameter kabel bisa 0.9mm, 2.0mm, 3.0mm.
•DWC sing disambungake kasedhiya karo pilihan konektor serat optik: LC / UPC, LC / APC, SC / UPC, SC / APC, FC / UPC, FC / APC, lan ST / UPC utawa liyane sing disesuaikan.
•Iki nduweni ukuran cilik, linuwih dhuwur, biaya murah lan keseragaman saluran-kanggo-saluran sing apik, lan akeh digunakake ing jaringan PON kanggo nyadari pemisahan daya sinyal optik.
•Kita nyedhiyakake kabeh seri produk splitter 1xN lan 2xN sing dirancang kanggo aplikasi tartamtu. Kabeh produk ketemu GR-1209-CORE lan GR-1221-CORE.
Aplikasi
+ Telekomunikasi Jarak Jauh.
+ Sistem CATV & Sensor Serat Optik.
+ Jaringan Area Lokal.
Fitur
• Low Keluwihan mundhut
• PDL kurang
• Stabil lingkungan
• Stabilitas termal sing apik
foto produk: