Distribusi Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)
Parameter teknis:
| Kabel Fiber Optik Dalam Ruangan Fanout (GJFJV) | diameteripun kabel | Bobot | |
| 2 intine | 4,5 mm | 22,00 kg/km | |
| 4 intine | 4,5 mm | 22,00 kg/km | |
| 6 iron | 4,5 mm | 23,00kg/km | |
| 8 iron | 5,5 mm | 27,00 kg/km | |
| 10 intine | 5,5 mm | 30,00kg/km | |
| 12 intine | 6,0 mm | 35,00kg/km | |
| Suhu panyimpenan (℃) | -20+60 | ||
| Radius Bending Min (mm) | jangka panjang | 10D | |
| Radius Bending Min (mm) | jangka cendhak | 20D | |
| Kekuwatan Tarik Min sing diidini (N) | jangka panjang | 200 | |
| Kekuwatan Tarik Min sing diidini (N) | jangka cendhak | 600 | |
| Beban Remuk (N/100mm) | jangka panjang | 200 | |
| Beban Remuk (N/100mm) | jangka cendhak | 1000 | |
Karakteristik serat:
| Gaya serat | Unit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| kahanan | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| atenuasi | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| panyebaran | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Bandwidth | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang dispersi nol | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Kemiringan dispersi nol | nm | ≤0,092 | ≤0,091 | ≤0,090 | ---- | ---- | ---- | ||
| PMD Serat Individu Maksimum | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Nilai Link Desain PMD | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Serat cutoff dawa gelombang λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Potongan kabeldawa gelombang λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumerikAperture (NA) | ---- | ---- | ---- | 0,200± 0,015 | 0,275±0,015 | 0,200±0,015 | |||
| Langkah (tegese bidirectionalpangukuran) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Irregularities liwat seratdawa lan titik | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Discontinuity | |||||||||
| Bedane backscatterkoefisien | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Keseragaman atenuasi | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| diameteripun inti | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Diameter cladding | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Cladding non-circularity | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| diameteripun lapisan | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Lapisan / chaffinchkesalahan konsentris | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Coating non circularity | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| kesalahan concentricity inti / cladding | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Curl (radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Konstruksi Kabel:
Kabel Cut-Out:
Kabel Multimode OM3 8 inti
Kabel mode tunggal 4 inti
Multimode 50/125 24 intine Kabel
katrangan:
•Distribusi Fanout Tight Buffer Indoor Fiber Optical Cable nggunakake 2 ~ 48 inti (utawa luwih) nggunakake 900μm utawa 600μm serat buffer nyenyet minangka kabel sub optik. Biasane tutup nggunakake PVC utawa LSZH, uga nggunakake PE utawa Nilon.
•Serat buffer nyenyet kebungkus karo lapisan saka tenunan aramid minangka anggota kekuatan, banjur rampung karo lapisan saka PVC utawa materi LSZH minangka metu jaket.
•Distribusi Fanout Ketat Buffer Kabel Serat Optik Dalam Ruangan warna jaket:
Mode tunggal: Kuning,
Multimode OM1 / OM2: Oranye,
Multimode OM3 / OM4: Aqua,
Multimode OM4: Violet,
Mutimode OM5: Jeruk Nipis.
Warna liyane opsional.
Aplikasi:
+ Digunakake ing pigtails lan kabel patch.
+ Digunakake minangka garis interconnect saka peralatan, lan digunakake ing sambungan optik ing optikkamar komunikasi, pusat data lan pigura distribusi optik.
+ Digunakake ing kabel njero ruangan, utamane digunakake minangka kabel distribusi.
ciri:
•Karakteristik mekanik lan lingkungan sing apik.
•Karakteristik flame retardant cocog karo syarat standar sing relevan.
•Karakteristik mekanik jacked memenuhi syarat standar sing relevan.
•Soft, fleksibel, gampang kanggo lay lan splice, lan karo transmisi data kapasitas gedhe.
•Ketemu macem-macem syarat pasar lan klien.
Aplikasi: digunakake kanggo kabel njero ruangan kipas-metu multi serat pigtail / kabel patch
+ Digunakake ing pigtails lan kabel patch.
+ Digunakake minangka garis interkoneksi peralatan, lan digunakake ing sambungan optik ing optik
kamar komunikasi lan pigura distribusi optik.
+ Digunakake ing kabel njero ruangan, utamane digunakake minangka kabel distribusi.
Packing: