Kabel Serat Optik Indoor Penyangga Ketat Distribusi Fanout (GJFJV)
Parameter Teknis:
| Kabel Serat Optik Indoor Fanout (GJFJV) | Diameter kabel | Bobot | |
| 2 inti | 4.5mm | 22.00kg/km | |
| 4 inti | 4.5mm | 22.00kg/km | |
| 6 inti | 4.5mm | 23.00kg/km | |
| 8 inti | 5.5mm | 27.00kg/km | |
| 10 inti | 5.5mm | 30.00kg/km | |
| 12 inti | 6.0mm | 35.00kg/km | |
| Suhu panyimpenan (℃) | -20+60 | ||
| Radius Lentur Min (mm) | Jangka panjang | 10D | |
| Radius Lentur Min (mm) | Jangka pendek | 20D | |
| Kekuatan Tarik Minimal sing Diidinake (N) | Jangka panjang | 200 | |
| Kekuatan Tarik Minimal sing Diidinake (N) | Jangka pendek | 600 | |
| Beban Remuk (N/100mm) | Jangka panjang | 200 | |
| Beban Remuk (N/100mm) | jangka pendek | 1000 | |
Karakteristik serat:
| Gaya serat | Unit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| kahanan | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| atenuasi | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Dispersi | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Bandwidth | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang dispersi nol | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Kemiringan dispersi nol | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| Serat Individu Maksimum PMD | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Nilai Link Desain PMD | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Panjang gelombang cutoff serat λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Pemotongan kabeldawa gelombang λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD (Material lan Keuangan) | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumerikBukaan (NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Langkah (rata-rata bidirectionalpangukuran) | dB | ≤0,05 | ≤0,05 | ≤0,05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Ketidakteraturan ing seratdawa lan titik | dB | ≤0,05 | ≤0,05 | ≤0,05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Diskontinuitas | |||||||||
| Bedane panyebaran balikkoefisien | dB/km | ≤0,05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Keseragaman atenuasi | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Diameter inti | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Diameter pelapis | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Cladding non-sirkular | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Diameter lapisan | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Lapisan/lendhutkesalahan konsentris | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Lapisan non-sirkular | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Kesalahan konsentrisitas inti/kladding | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Keriting (radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Konstruksi Kabel:
Kabel Pemotongan:
Kabel Multimode OM3 8 inti
Kabel 4 inti mode tunggal
Kabel Multimode 50/125 24 inti
Katrangan:
•Kabel Serat Optik Indoor Distribution Fanout Tight Buffer nggunakake 2 ~ 48 inti (utawa luwih) nggunakake serat buffer ketat 900μm utawa 600μm minangka sub kabel optik. Biasane nutupi nggunakake PVC utawa LSZH, uga nggunakake PE utawa Nilon.
•Serat penyangga kenceng dibungkus nganggo lapisan benang aramid minangka anggota kekuatan, banjur dilengkapi karo lapisan bahan PVC utawa LSZH minangka jaket njaba.
•Kabel Serat Optik Dalam Ruangan Distribusi Fanout Tight Buffer warna jaket njaba:
Mode tunggal: Kuning,
Multimode OM1 / OM2: Oranye,
Multimode OM3 / OM4: Banyu,
Multimode OM4: Ungu,
Mutimode OM5: Lime.
Werna liyane opsional.
Aplikasi:
+ Digunakake ing kuncir lan tali tempel.
+ Digunakake minangka jalur interkoneksi peralatan, lan digunakake ing sambungan optik ing optikkamar komunikasi, pusat data, lan pigura distribusi optik.
+ Digunakake ing kabel njero ruangan, utamane digunakake minangka kabel distribusi.
Ciri-ciri:
•Karakteristik mekanik lan lingkungan sing apik.
•Karakteristik tahan api nyukupi syarat standar sing relevan.
•Karakteristik mekanik saka dongkrak nyukupi syarat standar sing relevan.
•Alus, fleksibel, gampang dipasang lan disambung, lan kanthi transmisi data kapasitas gedhe.
•Ngepenuhi macem-macem kabutuhan pasar lan klien.
Aplikasi: digunakake kanggo kabel njero ruangan sing metu saka pirang-pirang serat pigtail/kabel patch
+ Digunakake ing kuncir lan tali tempel.
+ Digunakake minangka jalur interkoneksi peralatan, lan digunakake ing sambungan optik ing optik
kamar komunikasi lan pigura distribusi optik.
+ Digunakake ing kabel njero ruangan, utamane digunakake minangka kabel distribusi.
Pengepakan:









