Rating Maksimum Absolut
| Parameter | Simbol | Min. | Tipikal. | Maks. | Unit |
| Suhu Panyimpenan | Ts | -40 | - | 85 | ºC |
| SedulurKelembapan | RH | 5 | - | 95 | % |
| Tegangan Catu Daya | VCC | -0.3 | - | 4 | V |
| Tegangan Input Sinyal |
| Vcc-0.3 | - | Vcc+0.3 | V |
Kondisi Operasi sing Disaranake
| Parameter | Simbol | Min. | Tipikal. | Maks. | Unit | Cathetan |
| Suhu Operasi Kasus | Tkasus | 0 | - | 70 | ºC | Tanpa aliran udara |
| Tegangan Catu Daya | VCC | 3.14 | 3.3 | 3.47 | V |
|
| Arus Catu Daya | ICC | - |
| 300 | mA |
|
| Kecepatan Data | BR |
| 10.3125 |
| Gbps |
|
| Jarak Transmisi | TD |
| - | 300 | m |
|
| Serat sing digandheng | Multiserat mode | 50/125umMMF | ||||
Karakteristik Optik
| Parameter | Simbol | Min | Tipikal | Maks. | Unit | Ref. |
| Pemancar | ||||||
| Daya Pilihan Output | Cangkem | -6 | -1 | dBm | 1 | |
| Panjang Gelombang Optik | λ | 840 | 850 | 860 | nm | |
| Rasio Kepunahan Optik | ER | 3.0 | dB | |||
| RIN | RIN | -128 | dB/Hz | |||
| Masker Mata Output | Tundhuk karo IEEE 802.3ae | |||||
| Panampa | ||||||
| Sensitivitas Resep Dokter | RSENS | -10 | dBm | 2 | ||
| Daya Saturasi Input (Kelebihan Beban) | Psat | 0.5 | dBm | |||
| Rentang Panjang Gelombang | λC | 770 | 850 | 860 | nm | |
| LOS De -Assert | LOSD | -14 | dBm | |||
| LOS Assert | LOSA | -30 | dBm | |||
| Histeresis LOS | 0.5 | dB | ||||
Cathetan:
- Keamanan Laser Kelas 1 miturut peraturan FDA/CDRH lan IEC-825-1.
- Diukur nganggo PRBS 231-1 pola uji coba, @10.325Gb/s, BER<10-12.
IV. Karakteristik Listrik
| Parameter | Simbol | Min | Tipikal | Maks. | Unit | CATHETAN |
| Tegangan Pasokan | Vcc | 3.14 | 3.3 | 3.46 | V | |
| Arus Pasokan | Icc | 300 | mA | |||
| Pemancar | ||||||
| Impedansi diferensial input | Rin | 100 | Ω | 1 | ||
| Ayunan input data siji ujung | Vin,pp | 180 | 700 | mV | ||
| Tegangan Nonaktif Transmisi | VD | Vcc–1.3 | Vcc | V | ||
| Tegangan Aktifake Transmisi | VEN | Vee | Vee+ 0.8 | V | 2 | |
| Kirim Nonaktifake Negesake Wektu | 10 | us | ||||
| Panampa | ||||||
| Ayunan output data diferensial | Vout,pp | 300 | 850 | mV | 3 | |
| Wektu munggah output data | tr | 28 | ps | 4 | ||
| Wektu mudhun output data | tf | 28 | ps | 4 | ||
| Kasalahan LOS | Kesalahan VLOS | Vcc–1.3 | VccHOST | V | 5 | |
| LOS Normal | Norma VLOS | Vee | Vee+0.8 | V | 5 | |
| Penolakan Catu Daya | PSR | 100 | mVpp | 6 |
Cathetan:
- Disambungake langsung menyang pin input data TX. AC disambungake sawise iku.
- Utawa sirkuit terbuka.
- Ing terminasi diferensial 100 ohm.
- Iki minangka nilai 20-80% sing ora difilter
- Ilange Sinyal yaiku LVTTL. Logika 0 nuduhake operasi normal; logika 1 nuduhake ora ana sinyal sing dideteksi.
- Sensitivitas panrima wis tundhuk karo modulasi sinusoidal catu daya 20 Hz nganti 1,5 MHz nganti nilai tartamtu sing ditrapake liwat jaringan panyaring catu daya sing disaranake.
Dimensi Garis Besar