Kabel Patch Kipas MM OM5 12fo MPO Kanggo LC, 12serat MTP Kanggo LC 0.3m
Kabel Patch Kipas MM OM5 12fo MPO Kanggo LC, 12serat MTP Kanggo LC 0.3m
+ Kabel patch fan-out MPO menyang LC utawa MTP menyang LC nyambungake sakelar utawa transceiver jaringan MPO/MTP multi-serat kapadhetan dhuwur langsung menyang port LC diskrit kanthi kecepatan luwih endhek.
+ Iki nggabungake ruang lan nggampangake migrasi pusat data kanthi mbagi siji jalur backbone bandwidth dhuwur dadi sambungan individu sing bisa diatur.
+ Cacah Serat: 12fo
+ Jinis Serat: Multimode OM5 50/125
+ Jinis konektor:
MPO Lanang
MTP Lanang
MPO Wadon
MTP Wadon
+ Tipe Polaritas:
Tipe-A (Langsung)
Tipe-B (Rollover)
Tipe C (Salib Pasangan)
+ Konektor sisih A:
MPO-12
MTP-12
+ Ukuran konektor B:
Multimode LC
Multimode SC
Multimode ST
Multimode FC
Multimode E2000
+ Jinis kabel: 0.9mm, LSZH, tabung longgar
+ Dawane kabel: 30cm (0.3M)
Serat Multimode: OM3 vs OM4 vs OM5
+ Serat OM5, utawa Wideband Multimode Fiber (WBMMF), yaiku kabel optik ijo limau canggih sing dirancang kanggo pusat data kecepatan tinggi.
+ Iki ndhukung pirang-pirang dawa gelombang (850nm nganti 953nm) kanggo ngirim Ethernet 40G, 100G, lan 400G liwat sepasang serat, saengga bisa nyuda kerumitan lan biaya kabel kanthi signifikan.
+ OM5 utamane digawe kanggo jaringan perusahaan lan pusat data panyimpenan maya sing butuh nggabungake jumlah serat.
+ Inti/Cladding: 50/125um, padha karo OM3 lan OM4.
+ Wavelength Division Multiplexing (SWDM): Serat multimode pisanan sing digawe kanggo nggunakake SWDM, sing ngidini nggawa paling ora patang dawa gelombang sing kapisah ing sak pasang serat.
+ Bentenane utama antarane serat multi-mode OM3, OM4, lan OM5 yaiku kapasitas bandwidth, jarak transmisi maksimum, lan dhukungan kanggo multiplexing liwat jaringan jarak cendhak.
+ Perbandingan Penting
- Serat OM3: Dioptimalake kanggo 10Gbps nganti 40Gbps sajrone jarak bangunan sing cendhak.
- Serat OM4: Versi OM3 sing diupgrade kanthi bandwidth sing luwih dhuwur kanggo sambungan 40G/100G sing luwih dawa.
- Serat OM5: Dirancang khusus kanggo short-wavelength division multiplexing (SWDM) kanggo ngurangi jumlah kabel sakabèhé.
+ Kinerja Teknis:
| Fitur | OM3-300 | OM4 | OM5 |
| Werna Jaket | Aqua | Aqua / Violet | Ijo Jeruk Nipis |
| Diameter Inti | 50 μm | 50 μm | 50 μm |
| Pelapis Inti | 125 μm | 125 μm | 125 μm |
| Panjang gelombang sing didhukung | 850 nm | 850 nm | 850 nm nganti 953 nm |
| Jarak Maksimal Ethernet 10G | 300 meter | 550 meter | 550 meter |
| Jarak Maksimal 40G / 100G | 100 meter | 150 meter | 150 meter |
| Dhukungan SWDM | No | No | Ya (4 saluran) |
Aplikasi
+ Pusat data
+ Pusat data AI
+ Pusat konektivitas link bintang
+ Metro, Bank, ...
+ Konektivitas Piranti-menyang-Switch Langsung
+ Routing Backbone-to-Piranti
+ Patching Kapadhetan Dhuwur
Spesifikasi
| Tipe | Mode Tunggal | Mode Tunggal | Multi Mode | |||
|
| (APC Polandia) | (UPC Polandia) | (Poles PC) | |||
| Cacah Serat | 8, 12, 24 lan liya-liyane. | 8, 12, 24 lan liya-liyane. | 8, 12, 24 lan liya-liyane. | |||
| Tipe Serat | G652D, G657A1 lan liya-liyane. | G652D, G657A1 lan liya-liyane. | OM1, OM2, OM3, OM4, lan liya-liyane. | |||
| Kerugian Insersi Maks. | Elit | Standar | Elit | Standar | Elit | Standar |
|
| Kerugian Rendah |
| Kerugian Rendah |
| Kerugian Rendah |
|
|
| ≤0,35 dB | ≤0.75dB | ≤0,35 dB | ≤0.75dB | ≤0,35 dB | ≤0.60dB |
| Kerugian Pengembalian | ≥60 dB | ≥60 dB | NA | |||
| Kekuwatan | ≥500 kaping | ≥500 kaping | ≥500 kaping | |||
| Suhu Operasi | -40℃~+80℃ | -40℃~+80℃ | -40℃~+80℃ | |||
| Panjang Gelombang Uji | 1310nm | 1310nm | 1310nm | |||
| Tes sisipan-tarik | 1000 kali <0,5 dB | |||||
| Ijol-ijolan | <0,5 dB | |||||
| Gaya anti-tarik | 15kgf | |||||