Kabel Optik Aktif SFP+ 10Gb/s
Fitur-fitur
+ Ndhukung aplikasi Saluran Serat 10GBASE-SR/10G
+ Sesuai karo SFP+ MSA Listrik SFF-8431
+ Sesuai karo SFP+ Mekanik MSA SFF-8432
+ Multi rate nganti 11.3Gbps
+ Jarak transmisi nganti 150m (OM3)
Catu daya tunggal + +3.3V
+ Konsumsi daya sing sithik
+ Suhu kasus operasi: Komersial: 0°C nganti +70 °C
+ Sesuai karo RoHS
+ Proteksi sandhi kanggo A0h lan A2h
Aplikasi
+ 10GBASE-SR ing 10.31Gbps
+ InfiniBand QDR, SDR, DDR
+ Link optik liyane
Karakteristik Listrik
| Parameter | Simbol | Min. | Tipikal. | Maks. | Unit-unit | Cathetan | |
| Pemancar | |||||||
| Ayunan Input Data Diferensial | Ving,PP | 200 | - | 1600 | mVPP |
| |
| Impedansi Diferensial Input | ZIN | 90 | 100 | 110 | Ω |
| |
| Tx_Fault | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kesalahan Pemancar | VOH | 2.0 | - | VCC | V |
| |
| Tx_Disable | Operasi Normal | VIL | 0 | - | 0.8 | V |
|
| Nonaktifake Laser | VIH | 2.0 | - | VCC+0.3 | V |
| |
| Panampa | |||||||
| Output Tanggal Diferensial | Vmetu | 370 | - | 1600 | mV |
| |
| Impedansi Diferensial Output | ZD | 90 | 100 | 110 | Ω |
| |
| Rx_LOS | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kelangan Sinyal | VoH | 2.0 | - | VCC | V | ||
Karakteristik Optik
| Parameter | Simbol | Unit | Min | Tipikal | Maks. | Cathetan |
| Karakteristik pemancar optik | ||||||
| Kecepatan Data | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Rentang Panjang Gelombang Pusat | λc | nm | 820 | 850 | 880 |
|
| Daya Laser Mati | Poff | dBm | - | - | -45 |
|
| Bukak Daya Optik | P0 | dBm | -6.0 |
|
| 1 |
| Rasio Kepunahan | ER | dB | 3 | - | - |
|
| Jembar Spektral (RMS) | RMS | nm | - |
| 0.45 |
|
| Karakteristik Penerima Optik | ||||||
| Kecepatan Data | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Tingkat Kesalahan Bit | BER | dBm | - | - | E-12 | 2 |
| Daya Optik Input Kelebihan Beban | PIN | dBm | 2.4 | - | - | 2 |
| Rentang Panjang Gelombang Pusat | λc | nm | 820 | - | 880 |
|
| Sensitivitas Panrima ing Daya Rata-rata | Sen | dBm | - | - | -9.9 | 3 |
| Los Assert | LosA | dBm | -26 | - | - |
|
| Los De-Assert | LosD | dBm | - | - | -12 |
|
| Los Histeresis | LosH | dB | 0.5 | - | - | |
Cathetan:
- Digandhengake dadi 50/125 MMF.
- Diukur nganggo PRBS 231-1 pola uji coba @10.3125Gbps.BER=10E-12
Karakteristik Optik
| Parameter | Nilai | Unit-unit |
| Diameter | 3 | mm |
| Radius tikungan minimal | 30 | mm |
| Toleransi dawa | Dawane < 1 m: +5 /-0 | cm |
| 1 m ≤dawane ≤ 4,5 m: +15 / -0 | cm | |
| 5 m ≤dawane ≤ 14,5 m: +30 / -0 | cm | |
| Dawane ≥15.0 m +2% / -0 | m | |
| Werna kabel | Banyu (OM3); Oranye (OM2) | |