KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40km Transceiver
KCO-SFP+-10G-ER
+ KCO SFP+ 10G ER minangka standar kanggo Ethernet 10 Gigabit liwat kabel serat optik, sing dirancang khusus kanggo transmisi jarak adoh.
+ Iki ngidini transfer data nganti 40 km liwat serat mode tunggal (SMF) kanthi dawa gelombang 1550nm.
Modul serat optik +KCO SFP+ 10G ER, sing asring diimplementasikake minangka transceiver SFP+, digunakake ing macem-macem aplikasi sing mbutuhake jangkauan sing luwih jembar, kayata nyambungake bangunan ing kampus gedhe utawa ing jaringan area metropolitan.
Fitur Produk
+ Nganti 11.1Gbps Link Data
+ Transmisi nganti 40km nganggo SMF
+ Pemancar EML lan panrima PIN
+ Kandang logam, kanggo EMI sing luwih murah
+ Antarmuka 2-kabel kanthi pemantauan Diagnostik Digital terintegrasi
+ SFP sing bisa dipasang panas + jejak
+ Spesifikasi sing tundhuk karo SFF 8472
+ Sesuai karo SFP+ MSA nganggo konektor LC
+ Catu daya tunggal 3.3V
+ Kisaran suhu operasi casing: 0°C nganti 70°C
+ Disipasi daya < 1.5 W
Aplikasi
+ 10GBASE-ER/EW & 10G Ethernet
Standar
+ Sesuai karo SFF-8431
+ Tundhuk karo SFF 8472
+ Tundhuk karo RoHS.
Rating Maksimum Absolut
| Parameter | Simbol | Min. | Tipikal. | Maks. | Unit |
| Suhu Panyimpenan | Ts | -40 | - | 85 | ºC |
| Kelembapan Relatif | RH | 5 | - | 95 | % |
| Tegangan Catu Daya | VCC | -0.3 | - | 4 | V |
| Tegangan Input Sinyal |
| Vcc-0.3 | - | Vcc+0.3 | V |
Kondisi Operasi sing Disaranake
| Parameter | Simbol | Min. | Tipikal. | Maks. | Unit | Cathetan |
| Suhu Operasi Kasus | Tkasus | 0 | - | 70 | ºC | Tanpa aliran udara |
| Tegangan Catu Daya | VCC | 3.14 | 3.3 | 3.47 | V | |
| Arus Catu Daya | ICC | - | 450 | mA | ||
| Kecepatan Data | BR | 10.3125 | Gbps | |||
| Jarak Transmisi | TD | - | 40 | km | ||
| Serat sing digandheng | Serat mode tunggal | SMF 9/125um | ||||
Karakteristik Optik
| Parameter | Simbol | Min. | Tipikal. | Maks. | Unit | Cathetan |
| Pemancar | ||||||
| Daya Peluncuran Rata-rata | PO | -1 | +3 | dBm | Cathetan (1) | |
| Rasio Kepunahan | ER | 6 | dB | |||
| Panjang Gelombang Pusat | λc | 1530 | 1550 | 1565 | nm | |
| Jembar Pita Spektrum (RMS) | σ | 1.0 | nm | |||
| SMSR | 30 | dB | ||||
| Daya Output Pemancar MATI | POff | -30 | dBm | |||
| Hukuman Pemancar lan Dispersi | TDP (Tempat Tinggal) | 3.0 | dB | |||
| Masker Mata Output | Sesuai karo IEEE 802.3ae | |||||
| Panampa | ||||||
| Panjang Gelombang Optik Input | λ | 1270 | 1610 | nm | ||
| Sensitivitas Panrima | Psen | -15.8 | dBm | Cathetan (2) | ||
| Daya Saturasi Input (Kelebihan Beban) | Psat | 0.5 | dBm | |||
| Deteksi LOS - Negesake Daya | PA | -28 | dBm | |||
| Deteksi LOS - Daya Deassert | PD | -19 | dBm | |||
| Histeresis Deteksi LOS | PHYS | 0.5 | dB | |||
Cathetan:
1. Daya sing diluncurake (rata-rata) yaiku daya sing digandhengake menyang serat mode tunggal nganggo konektor master. (Sadurunge Urip)
2. Diukur nganggo sinyal uji kesesuaian kanggo BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ
Karakteristik Listrik
| Parameter | Simbol | Min | Tipikal | Maks. | Unit | CATHETAN |
| Tegangan Pasokan | Vcc | 3.14 | 3.3 | 3.46 | V | |
| Arus Pasokan | Icc | 450 | mA | |||
| Pemancar | ||||||
| Impedansi diferensial input | Rin | 100 | Ω | 1 | ||
| Ayunan input data siji ujung | Vin,pp | 180 | 700 | mV | ||
| Tegangan Nonaktif Transmisi | VD | Vcc–1.3 | Vcc | V | ||
| Tegangan Aktifake Transmisi | VEN | Vee | Vee+ 0.8 | V | 2 | |
| Kirim Nonaktifake Negesake Wektu | 10 | us | ||||
| Panampa | ||||||
| Ayunan output data diferensial | Vout,pp | 300 | 850 | mV | 3 | |
| Wektu munggah output data | tr | 28 | ps | 4 | ||
| Wektu mudhun output data | tf | 28 | ps | 4 | ||
| Kasalahan LOS | Kesalahan VLOS | Vcc–1.3 | VccHOST | V | 5 | |
| LOS Normal | Norma VLOS | Vee | Vee+0.8 | V | 5 | |
| Penolakan Catu Daya | PSR | 100 | mVpp | 6 |
Cathetan:
- Disambungake langsung menyang pin input data TX. AC disambungake sawise iku.
- Utawa sirkuit terbuka.
- Ing terminasi diferensial 100 ohm.
- 20 – 80%.
- Ilange Sinyal yaiku LVTTL. Logika 0 nuduhake operasi normal; logika 1 nuduhake ora ana sinyal sing dideteksi.
Sensitivitas panrima wis tundhuk karo modulasi sinusoidal catu daya 20 Hz nganti 1,5 MHz nganti nilai tartamtu sing ditrapake liwat jaringan panyaring catu daya sing disaranake.
Katrangan Pin
| Pin | Simbol | Jeneng/Katrangan | CATHETAN |
| 1 | VEET | Ground Pemancar (Padha karo Ground Penerima) | 1 |
| 2 | TKESALAHAN | Kasalahan Pemancar. | 2 |
| 3 | TDIS | Pemancar Dipateni. Output laser dipateni ing dhuwur utawa mbukak. | 3 |
| 4 | SDA | Jalur Data Antarmuka Serial 2-kawat | 4 |
| 5 | SCL | Antarmuka Serial 2-kawat Jam Baris | 4 |
| 6 | MOD_ABS | Modul Ora Ana. Dilebokaké ing njero modul | 4 |
| 7 | RS0 | Pilih Rating 0 | 5 |
| 8 | LOS | Indikasi Kehilangan Sinyal. Logika 0 nuduhake operasi normal. | 6 |
| 9 | RS1 | Ora perlu sambungan | 1 |
| 10 | VEER (Early Earning) | Ground Penerima (Padha karo Ground Pemancar) | 1 |
| 11 | VEER (Early Earning) | Ground Penerima (Padha karo Ground Pemancar) | 1 |
| 12 | RD- | Panrima DATA dibalik metu. AC Coupled | |
| 13 | RD+ | Panrima DATA non-inverted metu. AC Coupled | |
| 14 | VEER (Early Earning) | Ground Penerima (Padha karo Ground Pemancar) | 1 |
| 15 | VCCR (Certified Criteria) | Catu Daya Panrima | |
| 16 | VCCT (Kode Pos) | Catu Daya Pemancar | |
| 17 | VEET | Ground Pemancar (Padha karo Ground Penerima) | 1 |
| 18 | TD+ | Pemancar DATA Non-Terbalik mlebu. AC Digandhengake. | |
| 19 | TD- | Pemancar DATA sing diwalik mlebu. AC Digandhengake. | |
| 20 | VEET | Ground Pemancar (Padha karo Ground Penerima) | 1 |
Cathetan:
- Ground sirkuit diisolasi sacara internal saka ground chassis.
- TKESALAHANminangka output kolektor/drain terbuka, sing kudu ditarik munggah nganggo resistor 4,7k - 10k Ohm ing papan host yen dimaksudake kanggo digunakake. Tegangan tarik munggah kudu antarane 2,0V nganti Vcc + 0,3VA output dhuwur nuduhake kesalahan pemancar sing disebabake dening arus bias TX utawa daya output TX sing ngluwihi ambang batas alarm sing wis disetel. Output sing endhek nuduhake operasi normal. Ing kahanan endhek, output ditarik nganti <0,8V.
- Output laser dipateni ing TDIS>2.0V utawa mbukak, diaktifake ing TDIS<0.8V. (utawa <0.8V)
- Kudune ditarik munggah nganggo papan host 4.7kΩ-10kΩ menyang voltase antarane 2.0V lan 3.6V. MOD_ABS narik garis cendhek kanggo nandhakake modul wis dipasang.
- Ditarik mudhun sacara internal miturut SFF-8431 Rev 4.1.
- LOS iku output kolektor terbuka. Iki kudu ditarik munggah nganggo 4.7kΩ – 10kΩ ing papan host menyang voltase antarane 2.0V lan 3.6V. Logika 0 nuduhake operasi normal; logika 1 nuduhake ilang sinyal.
Fungsi Diagnostik Digital
Transceiver OP-SFP+-ER ndhukung protokol komunikasi serial 2-kawat kaya sing ditegesake ing SFP+MSA.
ID serial SFP standar nyedhiyakake akses menyang informasi identifikasi sing nggambarake kemampuan transceiver, antarmuka standar, pabrikan, lan informasi liyane.
Kajaba iku, transceiver SFP+ nyedhiyakake antarmuka pemantauan diagnostik digital sing ditingkatake kanthi unik, sing ngidini akses wektu nyata menyang parameter operasi piranti kayata suhu transceiver, arus bias laser, daya optik sing dikirim, daya optik sing ditampa, lan voltase pasokan transceiver. Iki uga nemtokake sistem alarm lan tandha peringatan sing canggih, sing menehi tandha marang pangguna pungkasan nalika parameter operasi tartamtu ana ing njaba kisaran normal sing disetel pabrik.
MSA SFP netepake peta memori 256-byte ing EEPROM sing bisa diakses liwat antarmuka serial 2-kawat ing alamat 8 bit 1010000X (A0h). Antarmuka pemantauan diagnostik digital nggunakake alamat 8 bit 1010001X (A2h), saengga peta memori ID serial sing ditetepake wiwitane tetep ora owah.
Informasi operasi lan diagnostik dipantau lan dilapurake dening Digital Diagnostics Transceiver Controller (DDTC) ing njero transceiver, sing diakses liwat antarmuka serial 2-kabel. Nalika protokol serial diaktifake, sinyal jam serial (SCL, Mod Def 1) digawe dening host. Tepi positif nglakokake jam data menyang transceiver SFP menyang segmen E2PROM sing ora dilindhungi tulisan. Tepi negatif nglakokake jam data saka transceiver SFP. Sinyal data serial (SDA, Mod Def 2) bi-directional kanggo transfer data serial. Host nggunakake SDA bebarengan karo SCL kanggo nandhani wiwitan lan pungkasan aktivasi protokol serial. Memori kasebut diatur minangka seri tembung data 8-bit sing bisa ditangani kanthi individu utawa kanthi runtut.
Sirkuit Antarmuka sing Disaranake
Dimensi Garis Besar
Kepatuhan Regulasi
| Fitur | Referensi | Kinerja |
| Discharge elektrostatik (ESD) | IEC/EN 61000-4-2 | Kompatibel karo standar |
| Gangguan Elektromagnetik (EMI) | FCC Bagian 15 Kelas B EN 55022 Kelas B (CISPR 22A) | Kompatibel karo standar |
| Keamanan Mata Laser | FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2 | Produk laser Kelas 1 |
| ROHS | 2002/95/EC | Kompatibel karo standar |
| EMC (Elektronik) | EN61000-3 | Kompatibel karo standar |
Lampiran A. Revisi Dokumen
| Versi No. | Tanggal | Katrangan |
| 1.0 | 2010-09-01 | Lembar data awal |
| 2.0 | 2011-09-10 | Nganyari format lan logo perusahaan |
| 3.0 | 2012-08-03 | Nganyari spesifikasi daya -1~4 dadi -1~3 |