KCO-Fiver-MTP-MPO-QSFP-Banner-kaca-1

KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40km Transceiver

Katrangan Cekak:

KCO SFP+ 10G ER minangka standar kanggo Ethernet 10 Gigabit liwat kabel serat optik, sing dirancang khusus kanggo transmisi jarak adoh.

Iki ngidini transfer data nganti 40 km liwat serat mode tunggal (SMF) kanthi dawa gelombang 1550nm.

Modul serat optik KCO SFP+ 10G ER, sing asring diimplementasikake minangka transceiver SFP+, digunakake ing macem-macem aplikasi ing ngendi jangkauan sing luwih dawa dibutuhake, kayata nyambungake bangunan ing kampus gedhe utawa ing jaringan area metropolitan.


Rincian Produk

Tag Produk

KCO-SFP+-10G-ER

+ KCO SFP+ 10G ER minangka standar kanggo Ethernet 10 Gigabit liwat kabel serat optik, sing dirancang khusus kanggo transmisi jarak adoh.

+ Iki ngidini transfer data nganti 40 km liwat serat mode tunggal (SMF) kanthi dawa gelombang 1550nm.

Modul serat optik +KCO SFP+ 10G ER, sing asring diimplementasikake minangka transceiver SFP+, digunakake ing macem-macem aplikasi sing mbutuhake jangkauan sing luwih jembar, kayata nyambungake bangunan ing kampus gedhe utawa ing jaringan area metropolitan.

Fitur Produk

+ Nganti 11.1Gbps Link Data

+ Transmisi nganti 40km nganggo SMF

+ Pemancar EML lan panrima PIN

+ Kandang logam, kanggo EMI sing luwih murah

+ Antarmuka 2-kabel kanthi pemantauan Diagnostik Digital terintegrasi

+ SFP sing bisa dipasang panas + jejak

+ Spesifikasi sing tundhuk karo SFF 8472

+ Sesuai karo SFP+ MSA nganggo konektor LC

+ Catu daya tunggal 3.3V

+ Kisaran suhu operasi casing: 0°C nganti 70°C

+ Disipasi daya < 1.5 W

Aplikasi

+ 10GBASE-ER/EW & 10G Ethernet

Standar

+ Sesuai karo SFF-8431

+ Tundhuk karo SFF 8472

+ Tundhuk karo RoHS.

Rating Maksimum Absolut

Parameter

Simbol

Min.

Tipikal.

Maks.

Unit

Suhu Panyimpenan

Ts

-40

-

85

ºC

Kelembapan Relatif

RH

5

-

95

%

Tegangan Catu Daya

VCC

-0.3

-

4

V

Tegangan Input Sinyal

Vcc-0.3

-

Vcc+0.3

V

Kondisi Operasi sing Disaranake

Parameter

Simbol

Min.

Tipikal.

Maks.

Unit

Cathetan

Suhu Operasi Kasus

Tkasus

0

-

70

ºC

Tanpa aliran udara

Tegangan Catu Daya

VCC

3.14

3.3

3.47

V

Arus Catu Daya

ICC

-

450

mA

Kecepatan Data

BR

10.3125

Gbps

Jarak Transmisi

TD

-

40

km

Serat sing digandheng

Serat mode tunggal

SMF 9/125um

Karakteristik Optik

Parameter

Simbol

Min.

Tipikal.

Maks.

Unit

Cathetan

Pemancar

Daya Peluncuran Rata-rata

PO

-1

+3

dBm

Cathetan (1)

Rasio Kepunahan

ER

6

dB

Panjang Gelombang Pusat

λc

1530

1550

1565

nm

Jembar Pita Spektrum (RMS)

σ

1.0

nm

SMSR

30

dB

Daya Output Pemancar MATI

POff

-30

dBm

Hukuman Pemancar lan Dispersi

TDP (Tempat Tinggal)

3.0

dB

Masker Mata Output

Sesuai karo IEEE 802.3ae

Panampa

Panjang Gelombang Optik Input

λ

1270

1610

nm

Sensitivitas Panrima

Psen

-15.8

dBm

Cathetan (2)

Daya Saturasi Input (Kelebihan Beban)

Psat

0.5

dBm

Deteksi LOS - Negesake Daya

PA

-28

dBm

Deteksi LOS - Daya Deassert

PD

-19

dBm

Histeresis Deteksi LOS

PHYS

0.5

dB

Cathetan:
1. Daya sing diluncurake (rata-rata) yaiku daya sing digandhengake menyang serat mode tunggal nganggo konektor master. (Sadurunge Urip)
2. Diukur nganggo sinyal uji kesesuaian kanggo BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Karakteristik Listrik

Parameter

Simbol

Min

Tipikal

Maks.

Unit

CATHETAN

Tegangan Pasokan

Vcc

3.14

3.3

3.46

V

Arus Pasokan

Icc

450

mA

Pemancar

Impedansi diferensial input

Rin

100

Ω

1

Ayunan input data siji ujung

Vin,pp

180

700

mV

Tegangan Nonaktif Transmisi

VD

Vcc–1.3

Vcc

V

Tegangan Aktifake Transmisi

VEN

Vee

Vee+ 0.8

V

2

Kirim Nonaktifake Negesake Wektu

10

us

Panampa

Ayunan output data diferensial

Vout,pp

300

850

mV

3

Wektu munggah output data

tr

28

ps

4

Wektu mudhun output data

tf

28

ps

4

Kasalahan LOS

Kesalahan VLOS

Vcc–1.3

VccHOST

V

5

LOS Normal

Norma VLOS

Vee

Vee+0.8

V

5

Penolakan Catu Daya

PSR

100

mVpp

6

Cathetan:

  1. Disambungake langsung menyang pin input data TX. AC disambungake sawise iku.
  2. Utawa sirkuit terbuka.
  3. Ing terminasi diferensial 100 ohm.
  4. 20 – 80%.
  5. Ilange Sinyal yaiku LVTTL. Logika 0 nuduhake operasi normal; logika 1 nuduhake ora ana sinyal sing dideteksi.

Sensitivitas panrima wis tundhuk karo modulasi sinusoidal catu daya 20 Hz nganti 1,5 MHz nganti nilai tartamtu sing ditrapake liwat jaringan panyaring catu daya sing disaranake.

Katrangan Pin

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40km Transceiver (1)

Pin

Simbol

Jeneng/Katrangan

CATHETAN

1

VEET

Ground Pemancar (Padha karo Ground Penerima)

1

2

TKESALAHAN

Kasalahan Pemancar.

2

3

TDIS

Pemancar Dipateni. Output laser dipateni ing dhuwur utawa mbukak.

3

4

SDA

Jalur Data Antarmuka Serial 2-kawat

4

5

SCL

Antarmuka Serial 2-kawat Jam Baris

4

6

MOD_ABS

Modul Ora Ana. Dilebokaké ing njero modul

4

7

RS0

Pilih Rating 0

5

8

LOS

Indikasi Kehilangan Sinyal. Logika 0 nuduhake operasi normal.

6

9

RS1

Ora perlu sambungan

1

10

VEER (Early Earning)

Ground Penerima (Padha karo Ground Pemancar)

1

11

VEER (Early Earning)

Ground Penerima (Padha karo Ground Pemancar)

1

12

RD-

Panrima DATA dibalik metu. AC Coupled

13

RD+

Panrima DATA non-inverted metu. AC Coupled

14

VEER (Early Earning)

Ground Penerima (Padha karo Ground Pemancar)

1

15

VCCR (Certified Criteria)

Catu Daya Panrima

16

VCCT (Kode Pos)

Catu Daya Pemancar

17

VEET

Ground Pemancar (Padha karo Ground Penerima)

1

18

TD+

Pemancar DATA Non-Terbalik mlebu. AC Digandhengake.

19

TD-

Pemancar DATA sing diwalik mlebu. AC Digandhengake.

20

VEET

Ground Pemancar (Padha karo Ground Penerima)

1

Cathetan:

  1. Ground sirkuit diisolasi sacara internal saka ground chassis.
  2. TKESALAHANminangka output kolektor/drain terbuka, sing kudu ditarik munggah nganggo resistor 4,7k - 10k Ohm ing papan host yen dimaksudake kanggo digunakake. Tegangan tarik munggah kudu antarane 2,0V nganti Vcc + 0,3VA output dhuwur nuduhake kesalahan pemancar sing disebabake dening arus bias TX utawa daya output TX sing ngluwihi ambang batas alarm sing wis disetel. Output sing endhek nuduhake operasi normal. Ing kahanan endhek, output ditarik nganti <0,8V.
  3. Output laser dipateni ing TDIS>2.0V utawa mbukak, diaktifake ing TDIS<0.8V. (utawa <0.8V)
  4. Kudune ditarik munggah nganggo papan host 4.7kΩ-10kΩ menyang voltase antarane 2.0V lan 3.6V. MOD_ABS narik garis cendhek kanggo nandhakake modul wis dipasang.
  5. Ditarik mudhun sacara internal miturut SFF-8431 Rev 4.1.
  6. LOS iku output kolektor terbuka. Iki kudu ditarik munggah nganggo 4.7kΩ – 10kΩ ing papan host menyang voltase antarane 2.0V lan 3.6V. Logika 0 nuduhake operasi normal; logika 1 nuduhake ilang sinyal.

Fungsi Diagnostik Digital

Transceiver OP-SFP+-ER ndhukung protokol komunikasi serial 2-kawat kaya sing ditegesake ing SFP+MSA.

ID serial SFP standar nyedhiyakake akses menyang informasi identifikasi sing nggambarake kemampuan transceiver, antarmuka standar, pabrikan, lan informasi liyane.

Kajaba iku, transceiver SFP+ nyedhiyakake antarmuka pemantauan diagnostik digital sing ditingkatake kanthi unik, sing ngidini akses wektu nyata menyang parameter operasi piranti kayata suhu transceiver, arus bias laser, daya optik sing dikirim, daya optik sing ditampa, lan voltase pasokan transceiver. Iki uga nemtokake sistem alarm lan tandha peringatan sing canggih, sing menehi tandha marang pangguna pungkasan nalika parameter operasi tartamtu ana ing njaba kisaran normal sing disetel pabrik.

MSA SFP netepake peta memori 256-byte ing EEPROM sing bisa diakses liwat antarmuka serial 2-kawat ing alamat 8 bit 1010000X (A0h). Antarmuka pemantauan diagnostik digital nggunakake alamat 8 bit 1010001X (A2h), saengga peta memori ID serial sing ditetepake wiwitane tetep ora owah.

Informasi operasi lan diagnostik dipantau lan dilapurake dening Digital Diagnostics Transceiver Controller (DDTC) ing njero transceiver, sing diakses liwat antarmuka serial 2-kabel. Nalika protokol serial diaktifake, sinyal jam serial (SCL, Mod Def 1) digawe dening host. Tepi positif nglakokake jam data menyang transceiver SFP menyang segmen E2PROM sing ora dilindhungi tulisan. Tepi negatif nglakokake jam data saka transceiver SFP. Sinyal data serial (SDA, Mod Def 2) bi-directional kanggo transfer data serial. Host nggunakake SDA bebarengan karo SCL kanggo nandhani wiwitan lan pungkasan aktivasi protokol serial. Memori kasebut diatur minangka seri tembung data 8-bit sing bisa ditangani kanthi individu utawa kanthi runtut.

Sirkuit Antarmuka sing Disaranake

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40km Transceiver (2)

Dimensi Garis Besar

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40km Transceiver (3)

Kepatuhan Regulasi

Fitur

Referensi

Kinerja

Discharge elektrostatik (ESD)

IEC/EN 61000-4-2

Kompatibel karo standar

Gangguan Elektromagnetik (EMI)

FCC Bagian 15 Kelas B EN 55022 Kelas B (CISPR 22A)

Kompatibel karo standar

Keamanan Mata Laser

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

Produk laser Kelas 1

ROHS

2002/95/EC

Kompatibel karo standar

EMC (Elektronik)

EN61000-3

Kompatibel karo standar

Lampiran A. Revisi Dokumen

Versi No.

Tanggal

Katrangan

1.0

2010-09-01

Lembar data awal

2.0

2011-09-10

Nganyari format lan logo perusahaan

3.0

2012-08-03

Nganyari spesifikasi daya -1~4 dadi -1~3


  • Sadurunge:
  • Sabanjure:

  • Tulis pesenmu ing kene lan kirim menyang kita