Kabel Serat Optik Luar Ruangan Pipa 12 Inti G652D G657A1 GYTS Mode Tunggal
Data Teknis Kabel GYTS
| Barang | Parameter | |
| Tabung longgar | Bahan | PBT (Pandhuan Panggunaan Pribadi) |
| Werna | Spektrum warna lengkap | |
| Pengisi | Bahan | PE |
| Werna | Ireng | |
| CSM | Bahan | Kawat baja fosfat |
| Waja | Bahan | Strip aluminium dilapisi plastik |
| Jaket njaba | Bahan | MDPE |
| Werna | Ireng | |
| Radius lentur minimal | Statis | 10 kali diameter kabel |
| Dinamis | 20 kali diameter kabel | |
| Mlengkung bola-bali | Muatan:150N; cacahing siklus: 30 Ora ana atenuasi tambahan sing jelas, ora ana serat sing putus lan ora ana kerusakan kabel. | |
| Kinerja tarik | Jangka pendek | 1500N |
| Nabrak | Jangka pendek | 1000N/100mm |
| Torsi | Muatan:150N; cacahing siklus: 10; sudut puntiran:±180° Ora ana tambahan sing jelas, ora ana serat sing putus lan ora ana kerusakan kabel. | |
| Dampak | Energi dampak:450g×1m; radius endhas palu: 12.5mm; jumlah tabrakan: 5 Ora ana atenuasi tambahan sing jelas, ora ana serat sing putus lan ora ana kerusakan kabel. | |
Karakteristik serat:
| Gaya serat | Unit | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Kondisi | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Atenuasi | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Dispersi | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bandwidth | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang dispersi nol | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Kemiringan dispersi nol | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| Serat Individu Maksimum PMD | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Nilai Link Desain PMD | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Panjang gelombang cutoff serat λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Pemotongan kabel dawa gelombang λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD (Material lan Keuangan) | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numerik Bukaan (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Langkah (rata-rata bidirectional pangukuran) | dB | ≤0,05 | ≤0,05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Ketidakteraturan ing dawa lan titik serat | dB | ≤0,05 | ≤0,05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Bedane panyebaran balik koefisien | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Keseragaman atenuasi | dB/km | ≤0.01 | ≤0.01 | |||||
| Diameter inti | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Diameter pelapis | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Cladding non-sirkular | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Diameter lapisan | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Lapisan/lendhut kesalahan konsentris | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Lapisan non-sirkular | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Kesalahan konsentrisitas inti/kladding | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Keriting (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Werna serat:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Biru | Jeruk | Ijo | Coklat | Abu-abu | Putih |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Abang | Ireng | Kuning | Ungu | Jambon | Aqua |
Katrangan Kabel GYTS
+ GYTS (anggota panguat logam, tabung longgar sing diuntai lan diisi, kabel serat optik njaba ruangan sing dilapisi baja-polietilen kanggo komunikasi).
+ Struktur kabel optik iki kanggo nutupi serat optik mode tunggal utawa multi-mode menyang isine njero sing digawe saka plastik modulus dhuwur. Senyawa tahan banyu ing tabung sing longgar.
+ Pusat inti kabel kuwi inti sing dikuatake logam. Kanggo sawetara kabel serat optik, inti sing dikuatake logam uga diekstrusi nganggo lapisan polietilen (PE).
+ Tabung sing longgar (lan tali pengisi) dipelintir ing sekitar inti penguat tengah kanggo mbentuk inti kabel sing kompak lan bunder, lan celah ing inti kabel diisi karo senyawa sing ngalangi banyu.
+ Pita komposit baja-plastik dibungkus kanthi longitudinal banjur diekstrusi nganggo selubung polietilen.
Konstruksi Kabel GYTS:
Karakteristik Kabel GYTS:
+ Performa mekanik lan suhu sing apik
+ Tabung longgar kekuatan dhuwur sing tahan hidrolisis
+ Senyawa pengisi tabung khusus njamin perlindungan serat sing penting
+ Struktur kompak sing dirancang khusus apik kanggo nyegah tabung sing longgar supaya ora susut
+ Selubung PE nglindhungi kabel saka radiasi ultraviolet
+ Langkah-langkah ing ngisor iki ditindakake kanggo mesthekake kabel kedap banyu:
+ Kawat baja digunakake minangka anggota kekuatan pusat
+ Senyawa pengisi tabung longgar
+ 100% pengisian inti kabel
+ Wis dites 100% sadurunge dikirim.
+ Dawane gulungan kabel: 1km, 2km, 3km, 5km
Aplikasi Kabel GYTA:
+ Diadopsi kanggo distribusi njaba ruangan.
+ Cocok kanggo pemasangan pipa, pemakaman langsung, metode ing sangisore lemah.
+ Komunikasi jaringan area lokal lan jarak jauh.
Pengepakan: