10Gb/s SFP + Kabel Optik Aktif
Fitur
+ Ndhukung aplikasi Saluran Serat 10GBASE-SR/10G
+ Selaras karo SFP + Listrik MSA SFF-8431
+ Selaras karo SFP + Mechanical MSA SFF-8432
+ Multi rate nganti 11.3Gbps
+ Jarak transmisi nganti 150m (OM3)
+ + 3.3V sumber daya tunggal
+ Konsumsi daya sing sithik
+ Suhu kasus operasi: Komersial: 0°C nganti +70°C
+ RoHS tundhuk
+ Pangreksan sandhi kanggo A0h lan A2h
Aplikasi
+ 10GBASE-SR ing 10,31Gbps
+ InfiniBand QDR, SDR, DDR
+ Link optik liyane
Karakteristik Listrik
| Paramèter | Simbol | Min. | Tipe. | Maks. | Unit | Cathetan | |
| Pemancar | |||||||
| Swing Input Data Diferensial | Ving, pp | 200 | - | 1600 | mVPP |
| |
| Impedansi Diferensial Input | ZIN | 90 | 100 | 110 | Ω |
| |
| Tx_Fault | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kesalahan Pemancar | VOH | 2.0 | - | VCC | V |
| |
| Tx_Disable | Operasi Normal | VIL | 0 | - | 0.8 | V |
|
| Laser Pateni | VIH | 2.0 | - | VCC+0.3 | V |
| |
| panrima | |||||||
| Output Tanggal Diferensial | Vmetu | 370 | - | 1600 | mV |
| |
| Impedansi Diferensial Output | ZD | 90 | 100 | 110 | Ω |
| |
| Rx_LOS | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kelangan Sinyal | VoH | 2.0 | - | VCC | V | ||
Karakteristik Optik
| Paramèter | Simbol | Unit | Min | Tipe | Maks | Cathetan |
| Karakteristik pemancar optik | ||||||
| Data Rate | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Rentang Panjang Gelombang Tengah | λc | nm | 820 | 850 | 880 |
|
| Daya Mati Laser | Poff | dBm | - | - | -45 |
|
| Bukak Daya Optik | P0 | dBm | -6.0 |
|
| 1 |
| Rasio kepunahan | ER | dB | 3 | - | - |
|
| Lebar Spektral (RMS) | RMS | nm | - |
| 0.45 |
|
| Karakteristik panrima optik | ||||||
| Data Rate | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Bit Error Rate | BER | dBm | - | - | E-12 | 2 |
| Kakehan Input Daya Optik | PIN | dBm | 2.4 | - | - | 2 |
| Rentang Panjang Gelombang Tengah | λc | nm | 820 | - | 880 |
|
| Sensitivitas panrima ing Daya Rata-rata | Sen | dBm | - | - | -9.9 | 3 |
| Los Assert | LosA | dBm | -26 | - | - |
|
| Los De-Assert | LosD | dBm | - | - | -12 |
|
| Los Hysteresis | LosH | dB | 0.5 | - | - | |
Cathetan:
- Disambungake menyang 50/125 MMF.
- Diukur nganggo PRBS 231-1 pola tes @10.3125Gbps.BER=10E-12
Karakteristik Optik
| Paramèter | Nilai | Unit |
| Dhiameter | 3 | mm |
| Radius tikungan minimal | 30 | mm |
| Toleransi dawa | Dawane < 1 m: +5 /-0 | cm |
| 1 m ≤dawa ≤ 4,5 m: +15 / -0 | cm | |
| 5 m ≤dawa ≤ 14,5 m: +30 / -0 | cm | |
| Length≥15,0 m + 2% / -0 | m | |
| Warna kabel | Aqua (OM3); Oranye (OM2) | |