KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver
KCO-SFP+-10G-ER
+ KCO SFP + 10G ER standar kanggo 10 Gigabit Ethernet liwat kabel serat optik, dirancang khusus kanggo transmisi long-distance.
+ Ngidini transfer data nganti 40 km liwat serat mode tunggal (SMF) kanthi dawa gelombang 1550nm.
+ KCO SFP + 10G ER modul serat optik, asring dipun ginakaken minangka SFP + transceiver, digunakake ing macem-macem aplikasi ngendi tekan lengkap dibutuhake, kayata bangunan nyambungake ing kampus gedhe utawa ing jaringan wilayah metropolitan.
Fitur produk
+ Nganti 11.1Gbps Data Links
+ Nganti 40km transmisi ing SMF
+ EML pemancar lan panrima PIN
+ pager logam, kanggo EMI ngisor
+ Antarmuka 2-kabel kanthi pemantauan Diagnostik Digital terpadu
+ Hot-pluggable SFP + tilas
+ Spesifikasi sing cocog karo SFF 8472
+ Selaras karo SFP + MSA karo konektor LC
+ Sumber daya tunggal 3.3V
+ Kisaran suhu operasi kasus: 0°C nganti 70°C
+ Boros daya <1,5 W
Aplikasi
+ 10GBASE-ER/EW & 10G Ethernet
Standar
+ Selaras karo SFF-8431
+ Selaras karo SFF 8472
+ RoHS Compliant.
Ratings maksimum Absolute
| Paramèter | Simbol | Min. | Tipe. | Maks. | Unit |
| Suhu panyimpenan | Ts | -40 | - | 85 | ºC |
| Kelembapan Relatif | RH | 5 | - | 95 | % |
| Tegangan Pasokan Daya | VCC | -0.3 | - | 4 | V |
| Tegangan Input Sinyal |
| Vcc-0.3 | - | Vcc+0.3 | V |
Kahanan Operasi sing Disaranake
| Paramèter | Simbol | Min. | Tipe. | Maks. | Unit | Cathetan |
| Suhu Operasi Kasus | Tkasus | 0 | - | 70 | ºC | Tanpa aliran hawa |
| Tegangan Pasokan Daya | VCC | 3.14 | 3.3 | 3.47 | V | |
| Power Supply Saiki | ICC | - | 450 | mA | ||
| Data Rate | BR | 10.3125 | Gbps | |||
| Jarak Transmisi | TD | - | 40 | km | ||
| Serat gandheng | Serat mode tunggal | 9/125um SMF | ||||
Karakteristik Optik
| Paramèter | Simbol | Min. | Tipe. | Maks. | Unit | Cathetan |
| Pemancar | ||||||
| Daya Dibukak Rata-rata | PO | -1 | +3 | dBm | Cathetan (1) | |
| Rasio kepunahan | ER | 6 | dB | |||
| Panjang gelombang tengah | λc | 1530 | 1550 | 1565 | nm | |
| Lebar Pita Spektrum (RMS) | σ | 1.0 | nm | |||
| SMSR | 30 | dB | ||||
| Transmitter OFF Daya Output | POff | -30 | dBm | |||
| Transmitter lan Paukuman sawur | TDP | 3.0 | dB | |||
| Topeng Mripat Output | Selaras karo IEEE 802.3ae | |||||
| panrima | ||||||
| Input Panjang Gelombang Optik | λ | 1270 | 1610 | nm | ||
| Sensitivitas panrima | Psen | -15.8 | dBm | Cathetan (2) | ||
| Daya Saturasi Input (Kakehan) | Psat | 0.5 | dBm | |||
| LOS Ndeteksi -Negesake Power | PA | -28 | dBm | |||
| LOS Ndeteksi - Deassert Power | PD | -19 | dBm | |||
| LOS Ndeteksi Histeresis | FIS | 0.5 | dB | |||
Cathetan:
1. Daya sing diluncurake (rata-rata) yaiku daya sing digabung dadi serat mode siji kanthi konektor master. (Sadurunge Urip)
2. Diukur nganggo sinyal tes kesesuaian kanggo BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ
Karakteristik Listrik
| Paramèter | Simbol | Min | Tipe | Maks | Unit | CATETAN |
| Tegangan Pasokan | Vcc | 3.14 | 3.3 | 3.46 | V | |
| Pasokan Saiki | Icc | 450 | mA | |||
| Pemancar | ||||||
| Impedansi diferensial input | Rin | 100 | Ω | 1 | ||
| Swing input data tunggal | Vin, p | 180 | 700 | mV | ||
| Ngirim Pateni Tegangan | VD | Vcc–1.3 | Vcc | V | ||
| Transmit Aktifake Tegangan | VEN | Vee | Vee + 0.8 | V | 2 | |
| Kirim Pateni Wektu Assert | 10 | us | ||||
| panrima | ||||||
| Swing output data diferensial | Wulan, pp | 300 | 850 | mV | 3 | |
| wektu munggah output data | tr | 28 | ps | 4 | ||
| Output data wektu tiba | tf | 28 | ps | 4 | ||
| Kesalahan LOS | kesalahan VLOS | Vcc–1.3 | VccHOST | V | 5 | |
| LOS Normal | norma VLOS | Vee | Vee+0.8 | V | 5 | |
| Power Supply Tolak | PSR | 100 | mVpp | 6 |
Cathetan:
- Disambungake langsung menyang pin input data TX. AC digandhengake banjur.
- Utawa mbukak sirkuit.
- Ing 100 ohm mandap diferensial.
- 20 – 80 %.
- Loss Of Signal yaiku LVTTL. Logika 0 nuduhake operasi normal; logika 1 nuduhake sinyal ora dideteksi.
Sensitivitas panrima tundhuk karo modulasi sinusoidal sumber daya saka 20 Hz nganti 1,5 MHz nganti nilai tartamtu sing ditrapake liwat jaringan panyaring sumber daya sing disaranake.
Deskripsi Pin
| Pin | Simbol | Jeneng / Katrangan | CATETAN |
| 1 | VEET | Transmitter Ground (Umum karo Receiver Ground) | 1 |
| 2 | TLUPA | Kesalahan Pemancar. | 2 |
| 3 | TDIS | Transmitter Pateni. Output laser dipatèni ing dhuwur utawa mbukak. | 3 |
| 4 | SDA | 2-kabel Serial Interface Data Line | 4 |
| 5 | SCL | 2-kabel Serial Interface Jam Line | 4 |
| 6 | MOD_ABS | Modul Absen. Grounded ing modul | 4 |
| 7 | RS0 | Pilih Rate 0 | 5 |
| 8 | LOS | Mundhut indikasi Sinyal. Logika 0 nuduhake operasi normal. | 6 |
| 9 | RS1 | Ora ana sambungan sing dibutuhake | 1 |
| 10 | VEER | Receiver Ground (Umum karo Transmitter Ground) | 1 |
| 11 | VEER | Receiver Ground (Umum karo Transmitter Ground) | 1 |
| 12 | RD- | Receiver Inverted DATA metu. AC Coupled | |
| 13 | RD+ | Receiver Non-kuwalik DATA metu. AC Coupled | |
| 14 | VEER | Receiver Ground (Umum karo Transmitter Ground) | 1 |
| 15 | VCCR | Receiver Power Supply | |
| 16 | VCCT | Transmitter Power Supply | |
| 17 | VEET | Transmitter Ground (Umum karo Receiver Ground) | 1 |
| 18 | TD+ | Transmitter DATA Non-Kuwalik ing AC Coupled. | |
| 19 | TD- | Transmitter Inverted DATA ing. AC Coupled. | |
| 20 | VEET | Transmitter Ground (Umum karo Receiver Ground) | 1 |
Cathetan:
- Sirkuit lemah diisolasi sacara internal saka lemah sasis.
- TLUPApunika Penagih mbukak / output saluran, kang kudu ditarik munggah karo 4.7k - 10k Ohms resistor ing Papan inang yen dimaksudaké kanggo nggunakake. Narik munggah voltase kudu antarane 2.0V kanggo Vcc + 0.3VA output dhuwur nuduhake fault pemancar disebabake salah siji saiki bias TX utawa daya output TX ngluwihi batesan weker prasetel. Output sing kurang nuduhake operasi normal. Ing negara kurang, output ditarik kanggo <0.8V.
- Output laser dipatèni ing TDIS> 2.0V utawa mbukak, aktif ing TDIS<0.8V.
- Kudu ditarik munggah karo 4.7kΩ- 10kΩ Papan inang kanggo voltase antarane 2.0V lan 3.6V. MOD_ABS narik baris mudhun kanggo nuduhake modul wis kepasang.
- Internal ditarik mudhun saben SFF-8431 Rev 4.1.
- LOS minangka output kolektor terbuka. Sampeyan kudu ditarik munggah karo 4.7kΩ - 10kΩ ing Papan inang kanggo voltase antarane 2.0V lan 3.6V. Logika 0 nuduhake operasi normal; logika 1 nuduhake mundhut saka sinyal.
Fungsi Diagnostik Digital
Transceiver OP-SFP + -ER ndhukung protokol komunikasi serial 2-kabel kaya sing ditegesake ing SFP + MSA.
ID serial SFP standar nyedhiyakake akses menyang informasi identifikasi sing nggambarake kemampuan transceiver, antarmuka standar, pabrikan, lan informasi liyane.
Kajaba iku, transceiver SFP + nyedhiyakake antarmuka pemantauan diagnostik digital sing unik, sing ngidini akses wektu nyata menyang paramèter operasi piranti kayata suhu transceiver, arus bias laser, daya optik sing ditransmisikan, daya optik sing ditampa lan tegangan suplai transceiver. Iki uga nemtokake sistem weker lan panji bebaya sing canggih, sing menehi tandha marang pangguna pungkasan nalika paramèter operasi tartamtu ana ing njaba kisaran normal sing disetel pabrik.
SFP MSA nemtokake peta memori 256-bait ing EEPROM sing bisa diakses liwat antarmuka serial 2-kabel ing alamat 8 dicokot 1010000X (A0h). Antarmuka ngawasi diagnostik digital ndadekake nggunakake alamat 8 dicokot 1010001X (A2h), supaya asline ditetepake map memori ID serial tetep panggah.
Informasi operasi lan diagnostik dipantau lan dilapurake dening Digital Diagnostics Transceiver Controller (DDTC) ing njero transceiver, sing diakses liwat antarmuka serial 2-kabel. Nalika protokol serial diaktifake, sinyal jam serial (SCL, Mod Def 1) kui dening inang. Pinggiran positif jam data menyang transceiver SFP menyang segmen E2PROM sing ora dilindhungi nulis. Data jam pinggiran negatif saka transceiver SFP. Sinyal data serial (SDA, Mod Def 2) iku loro arah kanggo transfer data serial. Host nggunakake SDA magepokan karo SCL kanggo menehi tandha wiwitan lan pungkasan saka aktivasi protokol serial. Kenangan diatur minangka seri tembung data 8-bit sing bisa ditangani kanthi individu utawa kanthi urutan.
Dianjurake Circuit Antarmuka
Ukuran Outline
Kepatuhan Regulasi
| Fitur | Referensi | Kinerja |
| Discharge elektrostatik (ESD) | IEC/EN 61000-4-2 | Kompatibel karo standar |
| Interferensi Elektromagnetik (EMI) | FCC Part 15 Kelas B EN 55022 Kelas B (CISPR 22A) | Kompatibel karo standar |
| Laser Eye Safety | FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2 | produk laser kelas 1 |
| ROHS | 2002/95/EC | Kompatibel karo standar |
| EMC | EN61000-3 | Kompatibel karo standar |
Lampiran A. Revisi Dokumen
| Versi No. | Tanggal | Katrangan |
| 1.0 | 2010-09-01 | Lembar data awal |
| 2.0 | 10-09-2011 | Update format lan logo perusahaan |
| 3.0 | 2012-08-03 | Nganyari spek daya -1~4 dadi -1~3 |