Kaca spanduk

KCO-SFP+-10G-ER 10Gb/s 1550nm SFP+ 40kmTransceiver

Katrangan singkat:

KCO SFP + 10G ER standar kanggo 10 Gigabit Ethernet liwat kabel serat optik, dirancang khusus kanggo transmisi long-distance.

Iki ngidini transfer data nganti 40 km liwat serat mode tunggal (SMF) kanthi dawa gelombang 1550nm.

KCO SFP + 10G ER modul serat optik, asring dipun ginakaken minangka SFP + transceiver, digunakake ing macem-macem aplikasi ngendi tekan lengkap dibutuhake, kayata bangunan nyambungake ing kampus gedhe utawa ing jaringan wilayah metropolitan.


Detail Produk

Tag produk

KCO-SFP+-10G-ER

+ KCO SFP + 10G ER standar kanggo 10 Gigabit Ethernet liwat kabel serat optik, dirancang khusus kanggo transmisi long-distance.

+ Ngidini transfer data nganti 40 km liwat serat mode tunggal (SMF) kanthi dawa gelombang 1550nm.

+ KCO SFP + 10G ER modul serat optik, asring dipun ginakaken minangka SFP + transceiver, digunakake ing macem-macem aplikasi ngendi tekan lengkap dibutuhake, kayata bangunan nyambungake ing kampus gedhe utawa ing jaringan wilayah metropolitan.

Fitur produk

+ Nganti 11.1Gbps Data Links

+ Nganti 40km transmisi ing SMF

+ EML pemancar lan panrima PIN

+ pager logam, kanggo EMI ngisor

+ Antarmuka 2-kabel kanthi pemantauan Diagnostik Digital terpadu

+ Hot-pluggable SFP + tilas

+ Spesifikasi sing cocog karo SFF 8472

+ Selaras karo SFP + MSA karo konektor LC

+ Sumber daya tunggal 3.3V

+ Kisaran suhu operasi kasus: 0°C nganti 70°C

+ Boros daya <1,5 W

Aplikasi

+ 10GBASE-ER/EW & 10G Ethernet

Standar

+ Selaras karo SFF-8431

+ Selaras karo SFF 8472

+ RoHS Compliant.

Ratings maksimum Absolute

Paramèter

Simbol

Min.

Tipe.

Maks.

Unit

Suhu panyimpenan

Ts

-40

-

85

ºC

Kelembapan Relatif

RH

5

-

95

%

Tegangan Pasokan Daya

VCC

-0.3

-

4

V

Tegangan Input Sinyal

Vcc-0.3

-

Vcc+0.3

V

Kahanan Operasi sing Disaranake

Paramèter

Simbol

Min.

Tipe.

Maks.

Unit

Cathetan

Suhu Operasi Kasus

Tkasus

0

-

70

ºC

Tanpa aliran hawa

Tegangan Pasokan Daya

VCC

3.14

3.3

3.47

V

Power Supply Saiki

ICC

-

450

mA

Data Rate

BR

10.3125

Gbps

Jarak Transmisi

TD

-

40

km

Serat gandheng

Serat mode tunggal

9/125um SMF

Karakteristik Optik

Paramèter

Simbol

Min.

Tipe.

Maks.

Unit

Cathetan

Pemancar

Daya Dibukak Rata-rata

PO

-1

+3

dBm

Cathetan (1)

Rasio kepunahan

ER

6

dB

Panjang gelombang tengah

λc

1530

1550

1565

nm

Lebar Pita Spektrum (RMS)

σ

1.0

nm

SMSR

30

dB

Transmitter OFF Daya Output

POff

-30

dBm

Transmitter lan Paukuman sawur

TDP

3.0

dB

Topeng Mripat Output

Selaras karo IEEE 802.3ae

panrima

Input Panjang Gelombang Optik

λ

1270

1610

nm

Sensitivitas panrima

Psen

-15.8

dBm

Cathetan (2)

Daya Saturasi Input (Kakehan)

Psat

0.5

dBm

LOS Ndeteksi -Negesake Power

PA

-28

dBm

LOS Ndeteksi - Deassert Power

PD

-19

dBm

LOS Ndeteksi Histeresis

FIS

0.5

dB

Cathetan:
1. Daya sing diluncurake (rata-rata) yaiku daya sing digabung dadi serat mode siji kanthi konektor master. (Sadurunge Urip)
2. Diukur nganggo sinyal tes kesesuaian kanggo BER = 10^–12.@10.3125Gbps, PRBS=2^31-1,NRZ

Karakteristik Listrik

Paramèter

Simbol

Min

Tipe

Maks

Unit

CATETAN

Tegangan Pasokan

Vcc

3.14

3.3

3.46

V

Pasokan Saiki

Icc

450

mA

Pemancar

Impedansi diferensial input

Rin

100

Ω

1

Swing input data tunggal

Vin, p

180

700

mV

Ngirim Pateni Tegangan

VD

Vcc–1.3

Vcc

V

Transmit Aktifake Tegangan

VEN

Vee

Vee + 0.8

V

2

Kirim Pateni Wektu Assert

10

us

panrima

Swing output data diferensial

Wulan, pp

300

850

mV

3

wektu munggah output data

tr

28

ps

4

Output data wektu tiba

tf

28

ps

4

Kesalahan LOS

kesalahan VLOS

Vcc–1.3

VccHOST

V

5

LOS Normal

norma VLOS

Vee

Vee+0.8

V

5

Power Supply Tolak

PSR

100

mVpp

6

Cathetan:

  1. Disambungake langsung menyang pin input data TX. AC digandhengake banjur.
  2. Utawa mbukak sirkuit.
  3. Ing 100 ohm mandap diferensial.
  4. 20 – 80 %.
  5. Loss Of Signal yaiku LVTTL. Logika 0 nuduhake operasi normal; logika 1 nuduhake sinyal ora dideteksi.

Sensitivitas panrima tundhuk karo modulasi sinusoidal sumber daya saka 20 Hz nganti 1,5 MHz nganti nilai tartamtu sing ditrapake liwat jaringan panyaring sumber daya sing disaranake.

Deskripsi Pin

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (1)

Pin

Simbol

Jeneng / Katrangan

CATETAN

1

VEET

Transmitter Ground (Umum karo Receiver Ground)

1

2

TLUPA

Kesalahan Pemancar.

2

3

TDIS

Transmitter Pateni. Output laser dipatèni ing dhuwur utawa mbukak.

3

4

SDA

2-kabel Serial Interface Data Line

4

5

SCL

2-kabel Serial Interface Jam Line

4

6

MOD_ABS

Modul Absen. Grounded ing modul

4

7

RS0

Pilih Rate 0

5

8

LOS

Mundhut indikasi Sinyal. Logika 0 nuduhake operasi normal.

6

9

RS1

Ora ana sambungan sing dibutuhake

1

10

VEER

Receiver Ground (Umum karo Transmitter Ground)

1

11

VEER

Receiver Ground (Umum karo Transmitter Ground)

1

12

RD-

Receiver Inverted DATA metu. AC Coupled

13

RD+

Receiver Non-kuwalik DATA metu. AC Coupled

14

VEER

Receiver Ground (Umum karo Transmitter Ground)

1

15

VCCR

Receiver Power Supply

16

VCCT

Transmitter Power Supply

17

VEET

Transmitter Ground (Umum karo Receiver Ground)

1

18

TD+

Transmitter DATA Non-Kuwalik ing AC Coupled.

19

TD-

Transmitter Inverted DATA ing. AC Coupled.

20

VEET

Transmitter Ground (Umum karo Receiver Ground)

1

Cathetan:

  1. Sirkuit lemah diisolasi sacara internal saka lemah sasis.
  2. TLUPApunika Penagih mbukak / output saluran, kang kudu ditarik munggah karo 4.7k - 10k Ohms resistor ing Papan inang yen dimaksudaké kanggo nggunakake. Narik munggah voltase kudu antarane 2.0V kanggo Vcc + 0.3VA output dhuwur nuduhake fault pemancar disebabake salah siji saiki bias TX utawa daya output TX ngluwihi batesan weker prasetel. Output sing kurang nuduhake operasi normal. Ing negara kurang, output ditarik kanggo <0.8V.
  3. Output laser dipatèni ing TDIS> 2.0V utawa mbukak, aktif ing TDIS<0.8V.
  4. Kudu ditarik munggah karo 4.7kΩ- ​​10kΩ Papan inang kanggo voltase antarane 2.0V lan 3.6V. MOD_ABS narik baris mudhun kanggo nuduhake modul wis kepasang.
  5. Internal ditarik mudhun saben SFF-8431 Rev 4.1.
  6. LOS minangka output kolektor terbuka. Sampeyan kudu ditarik munggah karo 4.7kΩ - 10kΩ ing Papan inang kanggo voltase antarane 2.0V lan 3.6V. Logika 0 nuduhake operasi normal; logika 1 nuduhake mundhut saka sinyal.

Fungsi Diagnostik Digital

Transceiver OP-SFP + -ER ndhukung protokol komunikasi serial 2-kabel kaya sing ditegesake ing SFP + MSA.

ID serial SFP standar nyedhiyakake akses menyang informasi identifikasi sing nggambarake kemampuan transceiver, antarmuka standar, pabrikan, lan informasi liyane.

Kajaba iku, transceiver SFP + nyedhiyakake antarmuka pemantauan diagnostik digital sing unik, sing ngidini akses wektu nyata menyang paramèter operasi piranti kayata suhu transceiver, arus bias laser, daya optik sing ditransmisikan, daya optik sing ditampa lan tegangan suplai transceiver. Iki uga nemtokake sistem weker lan panji bebaya sing canggih, sing menehi tandha marang pangguna pungkasan nalika paramèter operasi tartamtu ana ing njaba kisaran normal sing disetel pabrik.

SFP MSA nemtokake peta memori 256-bait ing EEPROM sing bisa diakses liwat antarmuka serial 2-kabel ing alamat 8 dicokot 1010000X (A0h). Antarmuka ngawasi diagnostik digital ndadekake nggunakake alamat 8 dicokot 1010001X (A2h), supaya asline ditetepake map memori ID serial tetep panggah.

Informasi operasi lan diagnostik dipantau lan dilapurake dening Digital Diagnostics Transceiver Controller (DDTC) ing njero transceiver, sing diakses liwat antarmuka serial 2-kabel. Nalika protokol serial diaktifake, sinyal jam serial (SCL, Mod Def 1) kui dening inang. Pinggiran positif jam data menyang transceiver SFP menyang segmen E2PROM sing ora dilindhungi nulis. Data jam pinggiran negatif saka transceiver SFP. Sinyal data serial (SDA, Mod Def 2) iku loro arah kanggo transfer data serial. Host nggunakake SDA magepokan karo SCL kanggo menehi tandha wiwitan lan pungkasan saka aktivasi protokol serial. Kenangan diatur minangka seri tembung data 8-bit sing bisa ditangani kanthi individu utawa kanthi urutan.

Dianjurake Circuit Antarmuka

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (2)

Ukuran Outline

KCO-SFP+-10G-ER 10Gbs 1550nm SFP+ 40kmTransceiver (3)

Kepatuhan Regulasi

Fitur

Referensi

Kinerja

Discharge elektrostatik (ESD)

IEC/EN 61000-4-2

Kompatibel karo standar

Interferensi Elektromagnetik (EMI)

FCC Part 15 Kelas B EN 55022 Kelas B (CISPR 22A)

Kompatibel karo standar

Laser Eye Safety

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-1, 2

produk laser kelas 1

ROHS

2002/95/EC

Kompatibel karo standar

EMC

EN61000-3

Kompatibel karo standar

Lampiran A. Revisi Dokumen

Versi No.

Tanggal

Katrangan

1.0

2010-09-01

Lembar data awal

2.0

10-09-2011

Update format lan logo perusahaan

3.0

2012-08-03

Nganyari spek daya -1~4 dadi -1~3


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen ing kene lan kirim menyang kita